Features:
- 600 V Cat III safety rating
- 50% bigger display with bright white backlight
- Voltage, resistance, continuity, capacitance
- Input terminal for ac and dc current measurements to 10 A current
- Diode test, data hold
Accuracy Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).
Function |
Range |
Resolution |
Accuracy |
AC volts
(40 Hz to 500Hz)1 |
4.000 V
40.00 V
400.0 V
1000 V |
0.001 V
0.01 V
0.1 V
1 V |
1.0 % + 3 |
DC volts |
4.000 V
40.00 V
400.0 V
1000 V |
0.001 V
0.01 V
0.1 V
1 V |
0.5 % + 3 |
AC millivolts |
400.0 mV |
0.1 mV |
3.0 % + 3 |
DC millivolts |
400.0 mV |
0.1 mV |
1.0 % + 10 |
Diode test2 |
2.000 V |
0.001 V |
10% |
Resistance
(Ohms) |
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ |
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ |
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3 |
Capacitance3 |
40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF |
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF |
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5 |
AC current μA
(40 Hz to 400 Hz) |
400.0 μA
4000 μA |
0.1 μA
1 μA |
1.5 % + 3 |
AC current mA
(40 Hz to 400 Hz) |
40.00 mA
400.0 mA |
0.01 mA
0.1 mA |
1.5 % + 3 |
AC current A
(40 Hz to 400 Hz) |
4.000 A
10.00 A |
0.001 A
0.01 A |
1.5 % + 3 |
DC current μA |
400.0 μA
4000 μA |
0.1 μA
1 μA |
1.5 % + 3 |
DC current mA |
40.00 mA
400.0 mA |
0.01 mA
0.1 mA |
1.5 % + 3 |
DC current A |
4.000 A
10.00 A |
0.001 A
0.01 A |
1.5 % + 3 |
Backlight |
Yes |
1All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range). |
Function |
Overload Protection |
Input Impedance (Nominal) |
Common Mode Rejection Ratio |
Normal Mode Rejection Ratio |
AC volts |
1000 V 1 |
>10 MΩ <100 pF |
>60 dB at dc,
50 Hz or 60 Hz |
– |
AC millivolts |
400 mV |
>1MΩ, <100 pF |
>80 dB at 50 Hz or 60 Hz |
– |
DC volts |
1000 V 1 |
>10 MΩ <100 pF |
>100 dB at dc,
50 Hz or 60 Hz |
>60 dB at 50 Hz or 60 Hz |
DC millivolts |
400 mV |
>1MΩ, <100 pF |
>80 dB at 50 Hz or 60 Hz |
– |
1 106 V Hz Max |
General Specifications |
Maximum voltage between any terminal and earth ground |
1000 V |
Display (LCD) |
4000 counts, updates 3/sec |
Battery type |
2 AA, NEDA 15A, IEC LR6 |
Battery life |
500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.) |
Temperature |
Operating |
0 °C to 40 °C |
Storage |
-30 °C to 60 °C |
Relative Humidity |
Operating humidity |
Non-condensing (<10°C)
≤90% RH at 10 °C to 30 °C;
≤75% RH at 30 °C to 40 °C |
40 MΩ range
≤80% RH at 10 °C to 30 °C;
≤70% RH at 30 °C to 40 °C |
|
|
Reviews
There are no reviews yet.